  Datasheet File OCR Text:
  technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 1 highligh ts & features ? ultra compact size ? full power from - 10 c to +55 c operation ? universal ac input voltage ? up to 79 . 0 % efficiency ? extreme low temperature cold start at -40c ? nec class 2 / limited power source (lps) certified ? overvoltage / overcurrent / over temperature protections safety standards cb certified for worldwide use model number: drs-5 v3 0 w1 n z unit weight : 0 .1 1 kg (0.24 lb) dimensions (l x w x d): 75 x 21 x 89.5 mm ( 2.95 x 0.83 x 3.52 inch) general description the ultra - compact an d competitively priced delta sync din rail power supply series is designed for industrial applications requiring highly reliable power supply within a tight space. the sync series operates with universal ac input range and offers full pow er up to 55 c. the output is adjustable from 5.0 - 5.5 volts, and can support up to 3000 microfarads of load capacitance. a green led indicates output is present. all models in the series are certified according to iec/en/ul 60950 - 1 information technology equipment (ite) and ul 508 industrial control equipment (ice). the series is also fully compliant with rohs directive 2011/65/eu for environmental protection. nec class 2 and limited power source (lps) approvals are available for this product. model information sync din rai l power supply model number input v oltage range rated output v oltage rated output cur r ent drs-5 v3 0 w1 n z 85-264 v ac (120 - 375vdc) 5 vdc 3.0 a model numbering dr s ? 5 v 3 0 w 1 n z din rail product series s ? sync series output voltage 30w series single phase nec c lass 2 without dc ok relay contact
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 2 specifications input ratings / characteristics nominal input v oltage 100- 240 v ac input v oltage range 85-264 v ac nominal input f r equency 50- 60hz input f r equency range 47- 63hz dc input voltage range* 120- 375vdc input cur r ent < 0. 40a @ 1 15 vac, < 0. 20 a @ 2 30 vac ef ficiency at 100% load > 79. 0 % @ 115 vac & 230vac max power dissipation 0% load 100% load < 0. 3 w @ 115vac & 230vac < 4. 0 w @ 115vac & 230vac max inrush cur r ent (cold start) < 20 a @ 115 vac , < 4 0 a @ 23 0vac leakage cur r ent ( neutral to pe terminal) < 0.5 ma @ 264 vac *fulfills test conditions for dc input. safety approval for dc input can be obtained upon request. output ratings / characteristics ** nominal output voltage 5 vdc factory set point tolera nce 5 vdc 2% output voltage adjustment range 5.0 - 5.5 vdc output current 3 . 0 a (15 w max.) output power 15 w line regulation < 0.5 % (@ 85-2 64 vac , 100% load ) load regulation < 1 .0% (@ 85-2 64 vac, 0 - 100% load ) pard *** ( 20mhz) < 75mvpp @ > 0c to 70c < 150m vpp @ 0c to - 20c rise time < 3 0ms @ nominal input (100% load) start - up time < 2 , 0 00ms @ 1 15 vac (100% load) < 1, 0 00ms @ 2 30 vac (100% load) hold - up time > 2 0 ms @ 115 vac (100% load ) > 100ms @ 230vac (100% load) dynamic response (overshoot & undershoot o /p voltage) 5% @ 85 - 264vac input, 5 - 100% load (slew rate: 0.1a/s, 50% duty cycle @ 5hz to 1 k hz) start - up with capacitive loads 3 ,000f max **for power de - rating from < - 10c to - 20c, and 55c to 70c, see power de - rating on page 3. * **pard is measured with an ac coupling mode, 5cm wires, and in pa rallel with 0.1f ceramic capacitor & 47f electrolytic capacitor.
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 3 mechanical case cover / chassis plastic dimensions (l x w x d) 75 x 21 x 89.5 mm (2.95 x 0.83 x 3.52 inch) unit weight 0.11 kg (0.24 lb) indicator green led (dc ok) cooling sys tem convection terminal input 3 pins (rated 300v/ 16a) output 2 pins (rated 300v/ 16a) wire input / output awg 2 2 -12 / awg 20 - 12 mounting rail standard ts35 din rail in accordance with en 60715 noise (1 meter from power supply) sound pressure level (spl) < 25dba environment surrounding air temperature operating -2 0 c to + 7 0 c (cold start at - 40c @ 40% load ) storage -40 c to + 85 c power de - rating -1 0c to - 2 0c de - rate power by 2 % / c > 5 5 c de - rate power by 3.33 % / c operating humidity 5 to 95 % rh (non - condensing) operating altitude 0 to 2 ,000 meters (6,560 ft.) shock test non - operating iec60068 - 2 - 27, half sine wa ve: 50g for a duration of 11ms; 3 times per direction, 9 times in total operating iec 60068 -2 - 27, half sine wave : 10 g for a duration of 11ms; 1 time in x axis vibration non - operating iec 60068 -2 - 6, random: 5 -50 0hz ; 2.09 g rms , 2 0 min per axis for all x, y, z directions operating iec 60068 -2 - 6, sine wave : 10-50 0hz ; 2 g peak ; displacement of 0. 35mm; 1 octave per min; 60 min per axis for all x, y, z direction s pollution degree 2 protections overvoltage < 7.245 v, selv output, latch mode overload / overcurrent 105~1 4 0% of rated load current , hiccup mode, non - latching (auto - recovery) over temperature < 75c surrounding air t emperature @ 100% load, latch mode short circuit hiccup mode, non - latching (auto - recovery when the fault is removed) internal fuse t3.15a degree of protection ip 20 protection against shock class i with pe * connection *pe: primary earth
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 4 reliabilit y data mtbf telcordia sr -332 > 700,000 hrs i/p: 115vac & 230vac , o/p: 100% load, ta: 25c mil - hdbk -217f 305 ,000 hrs i/p: 115vac & 230vac , o/p: 100% load, ta: 25c expected cap life time 10 years ( 115ac & 2 30vac , 50% load @ 40c ) safety standards / directives safety entry low voltage selv (en 60950) electrical safety tuv bauart ul/cul recognized cb scheme en 60950- 1 ul 60950 - 1, csa c22.2 no. 60950-1 (file no. e1 9 1 395 ) i ec 60950 -1 , limited power source (lps) industrial control equipment ul/cul lis ted ul 508 and csa c22.2 no. 107.1 -01 (file no. e315335 ) class 2 power supply ul/cul recognized ul 60950 - 1, csa c22.2 no. 60950-1 (file no. e1 9 1 395) ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0 kvac input to ground 3 . 0 kvac output to ground 0.5kvac
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 5 emc emc / emissions generic standards: en 61000 -6 - 3, en 61000- 6 -4 cispr 22, en 55022 en 55011, fcc title 47: class b component power supply for general use en 61204 - 3 immunity to generic standards: en 55024 , en 61000 -6 - 1, en 61000-6 -2 electrostatic discharge iec 61000 -4 -2 level 3 criteria a 1) air discharge: 8kv contact discharge: 6 kv radiated field iec 61000 -4 -3 level 3 criteria a 1) 80mhz - 1ghz, 10v/m with 1khz tone / 80% modulation 1.4ghz - 2ghz, 3v/m with 1khz tone / 80% modulation 2ghz - 2.7ghz, 1v/m with 1khz tone / 80% modulation electrical fast transient / burst iec 61000 -4 -4 level 3 criteria a 1) 2 kv sur ge iec 61000 -4 -5 level 3 criteria a 1) common mode 3 ) : 2 kv differential mode 4 ) : 1 kv conducted iec 61000 -4 -6 level 3 criteria a 1) 150khz - 80mhz, 10 vrms power frequency magnetic fields iec 61000 -4 -8 criteria a 1) 30 a/meter voltage dips and interruptions iec 61000 -4 -11 0% of 100vac, 20ms 30% of 100vac, 1 0ms 30% of 100vac, 50 0ms 4 0% of 100vac, 2 0 0ms 70% of 100vac, 5 00ms 0% of 100vac, 5000ms 0% of 240vac, 20ms 7 0% of 24 0vac, 50 0ms 0% of 240vac, 500 0ms criteria a 1) criteria a 1) criteria b 2) criteria b 2) crit eria a 1) criteria b 2) criteria a 1) criteria a 1) criteria b 2) low energy pulse test (ring wave) iec 61000 -4 -12 level 3 criteria a 1) common mode 3 ) : 2 kv differential mode 4 ) : 1 kv harmonic current emission iec/en 61000 -3 - 2, class a voltage fluctuation and flicker iec/en 61000 -3 -3 1) criteria a: normal performance within the specification limits 2) criteria b: temporary degradation or loss of function which is self - recoverable 3) asymmetrical: common mode (line to earth) 4) symmetrical: differential mode (line to line)
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 6 block diagram device description 1) input terminal block connector 2) output terminal block connector 3) dc voltage adjustment potentiometer 4) dc ok led (green) 5) universal mounting system
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 7 dimensions l x w x d: 75 x 21 x 89.5 mm [ 2.95 x 0. 83 x 3.52 inch ] engineering data output load de - rating vs surrounding air temperature note 1. power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2. if the ou tput capacity is not reduced when the surrounding air temperature >55 c, the device will run into over temperature protection. when activated, power supply will latch off, until the surrounding air temperature is lowered or the load is reduced as far as ne cessary to keep the device in working condition, and require removal/re - application of input ac voltage in order to restart. 3. in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 80mm (3.14 inch) abo ve and below the device as well as a lateral distance of 25mm (0.98 inch) to other units while the device is in operation. 4. depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. if the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. fig. 1 de - rating for vertical mounting orientation - 10c to - 20c de - rate power by 2 % / c > 55c de - rate power by 3.3 3% / c
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 8 output load de - rating vs input voltage assembly & installation the power supply unit (psu) can be mounted on 35mm din rails in accordance with en60715. the device should be installed with input terminal block at the bottom. each device is delivered ready to install. mounting ? no output power de - rating across the entire input voltage range dismounting fig. 2.1 mounting snap on the din rail as shown in fig. 2.1: 1. tilt the unit slightly upwards and put it onto the din rail. 2. push downwards until stopped. 3. press against the bottom front side for locking. 4. shake the unit slightly t o ensure that it is secured. fig. 2.2 dismounting to uninstall, pull or slide down the latch with screw driver as shown in fig. 2.2. then slide the power supply unit (psu) in the opposite direction, release the latch and pull out the power supply unit (psu) from the rail.
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 9 safety instructions ? always switch mains of input power off before connecting and disconnecting the input voltage to the device . if mains are not turned off, there is risk of explosion / severe damage. ? to guarantee sufficient convection cooling, keep a distance of 8 0mm (3.14 inch) above and below the device as well as a lateral distance of 25mm (0.98 inch) to other units. ? note that the enclosure of the device can become very hot depending on the surround ing air temperature and output load connected to the device. risk of burns! ? the main power must be turned off before connecting or disconnecting the wires to the terminals! ? do not insert any objects into the device. ? dangerous voltages present for at least 5 minutes after disconnecting all sources of power. ? the power supplies unit should be installed in minimum ip54 rated enclosure. ? the power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor loc ation) that is relatively free of conductive contaminants.
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 10 functions graph illustrating the start - up time, rise time, and hold- up ti me start - up time the time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied . rise time the time required for the output voltage to change from 10% to 90% of its final steady state set va lue. hold - up time time between the collapse of the ac input voltage, and the output falling to 95% of its steady state set value. inrush current inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is fi rst applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponentially during subsequent cycles of ac voltage. dynamic response the power s upply output voltage will remains within 5% of its steady state value, when subjected to a dynamic load from 5 % to 100% of its rated current. ? 50% duty cycle / 5hz to 1 k hz
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 11 overload & overcurrent protections (auto - recovery) the power supply?s overload (olp) and overcurrent (ocp) protections will be activated when output current is 105~1 4 0% of i o (max load) . in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the po wer supply will go into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is removed and i o is back within the specifications. it is not recommended to prolong the duration of i o when it is <1 05-1 4 0% but > 100% , since it may cause damage to the psu. short circuit protection (auto - recovery) the power supply?s output short circuit protection function also provides protection against short circuits. when a short circuit is applied, the output curren t will operate in ?hiccup mode?. the power supply will return to normal operation after the short circuit is removed. overvoltage protection (latch mode) the power supply?s overvoltage circuit will be activated when its internal feedback circuit fail s. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. power supply will latch off, and require removal/re - application of input ac voltage in order to restart. the power supply should be latch. over temperatu re protection (latch mode) as described in load de - rating section, the power supply also has over temperature protection (otp). in the event of a higher operating temperature at 100% load; or, when the operating temperature is beyond what is recommended in the de - rating graph, the otp circuit will be activated. when activated, power supply will latch off, until the surrounding air temperature drops to its normal operating temperature or the load is reduced as recommended in the de - rating graph. removal/re-a pplication of input ac voltage will then be required in order to restart.
technical d at asheet sync din rail power supply 5v 15w 1 phase (nec class 2) / drs - 5v30w1nz all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (january 2016 , rev. 00) 12 others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation for ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard.


▲Up To Search▲   

 